City Box

  Maximum depth   3.70 m
  Maximum pipe diameter   1.33 m
  Panel lenghts   2.00 to 3.50 m

This small steel trench box is especially made for inner city shoring jobs. The ideal trench depth for this system is from 4,95’-1.50m up to 9.9’-3.0m. The top box with a height of 19.6”-0.50m is often used to shore just the top of a trench in more stable soil conditions. The boxes are made to be handled by mini- and smaller excavators. Even being a lightweight box these elements are very stable designed to use in both the cut and lower method as well as the lower onto the pre-excavated trench.

City Box
Base panelDimensions
L x H1 x D
Weight
Panel
Weight
Element
With 4
spindels
Type A
Pipe
Clearance
RDH
Pipe
Length

Area

Max.
Soil
Pressure
(TBG)
[mm][kg][kg][mm][mm][m²][kN/m²]
VB 60 3500x2400 3500x2400x60 642 1528 1355 3046 16.8 24.70
VB 60 3000x2400 3000x2400x60 542 1328 1355 2614 14.4 24.95
VB 60 2500x2400 2500x2400x60 432 1108 1355 2114 12.0 30.00
VB 60 2000x2400 2000x2400x60 373 990 1355 1614 9.6 37.50
Extension Panel L x H2 x D With 2 spindels Type B (700)
VB A 60 3500x1300 3500x1320x60 380 882   3064 9.24 24.70
VB A 60 3000x1300 3000x1320x60 287 696   2614 7.92 24.95
VB A 60 2500x1300 2500x1320x60 254 630   2114 6.60 30.00
VB A 60 2000x1300 2000x1320x60 222 566   1614 5.28 37.50