Sheetpile Frame

  Maximum depth   Depending on soil pressure
and static system
  Panel lenghts   2.00 to 6.50 m

The Piling frame box system is used for reliable guidance of trench sheets or light sheet piles. It is a fast and cost saving method and a practical and necessary addition to the use of large area steel shoring systems in urban areas where frequent crossing services are present. This proven shoring system enables the otherwise difficult problems associated with crossing utility lines in urban areas to be efficiently overcome. A highly capable shoring system in its own right, or when integrated as part of a larger shoring system, the Piling frame box shoring system represents a cost effective, flexible and practical solution to shoring problems.

Sheetpile Frame
Base panelDimensions
L x H1 x D
Weight
Panel
Weight
Element
With 4
spindels
Type A
Pipe
Clearance
RDH
Pipe
Length

Area

Max.
Soil
Pressure
(TBG)
[mm][kg][kg][mm][mm][m²][kN/m²]
KKP ST KD6 CP 4070x1000x305 986 2216   3652   56.1
KKP ST KD6 CPS 4154x1000x305 1028 2300   3652   46.2
KKP 2040x0600 2040x0600 261 574   1740   49.0
KKP 2840x0600 2840x0600 358 768   2540   28.5
The pipe clearance of the sheetpile frame depends on the statical system (walers, ground depth of the sheetpile) and the soil conditions.